Blogi :: 873 Posty
 

Safe Handling Of Neodymium Disc Magnet Based Upon Size

  Wiadomości i komentarze  

Almost every week we hear stories about damaged magnets, pinched fingers, or even worse, injuries to individuals caused by strong magnets. When we discuss this with our customers, we usually find a common theme…safe handling practices are not in place for each phase of the product development cycling.
  Use plastic tweezers and not metal.
  Keep Neodymium Disc Magnet in the same area at all times when not in use so they can be located easily. Spreading them out in a work area may make it hard to relocate them, or they may attract and stick to other ferrous materials.
  Neodymium micro magnets should never be placed under the skin due to allergies and possible complications related to exposure to neodymium, iron and boron.
  Use a microscope or magnifying glass when handling micro magnets to avoid damage to the magnets and for proper placement in the application.
  For applications using micro magnets in EVT, DVT, or mass production, packaging should be considered carefully to protect the magnets, make handling by the production staff easier, and ensure cleanliness of the magnet. Work with the magnet or magnetic assembly supplier to assist with packaging suggestions and requirements.
  Train staff how to handle micro magnets that contain parylene or other coatings that can be scratched or damaged easily. This is especially important in medical applications.
  Keep a medium-sized magnet available in case you need to pick up or locate micro magnets that are dropped on carpet, in a place that is tough to reach, or just not able to be seen.
  Keep the magnets in a clean environment to avoid foreign materials attracting to the magnets.
  Small Magnets 1.0mm – 6.35mm
  Small magnets can be more fragile and easily break if hitting something, especially another magnet.
  If these are less than 2.0mm they can easily get lost or attached to something other than the prototype. Keep in the same area when not in use so they can be easily located.
  Use spacers between magnets if possible so they can be separated easily. If no separator is used, slide the magnets apart to separate. When putting them back together without separators, do not slap them together, as this could cause cracking or chipping.
  It is safest to connect two magnets in the following way: Place the face of one magnet on the corner of another magnet. Once the face is against the corner of the other magnet, carefully slide them together so they are face-to-face.
  The packaging of small magnets is important when assembling these during production. Work with the supplier to develop packaging that is safe and effective for production staff.
  Keep the magnets in a clean environment to avoid foreign materials attracting to the magnets. If foreign bodies attach to a small magnet, pat the magnet with scotch tape or masking tape to remove any foreign materials.
  Fingers and hands get pinched, bleed or get broken when caught between magnets that snap together.
  Medium Magnets 6.35mm – 25.4mm
  These will become much stronger magnetically than small magnets and will attract to ferrous materials from a further distance. Keep steel tools at a distance from the magnets.
  Be aware of items close to the magnets that can jump toward the magnets and potentially break or chip them. For example, paperclips, pins, needles, magnetic wire, and small steel tools.
  Use spacers between the magnets that are about ½ the size of the largest dimension. For example, if a diameter is 1”, then use a non-magnetic spacer that is 0.5”. Suggested spacers are plastic, wood, and cardboard. When putting the magnets back together, use the spacer as a cushion and tool to help bring the magnets back together without damage. Remember, fingers and hands can get pinched, bleed or get broken when caught between magnets that snap together so be slow, precise and focused when handling them.
  The packaging of medium-sized magnets is critical in EVT, DVT, and mass production. Determine the appropriate packaging that includes the quantity per package, the packaging materials and the appropriate spacing needed between magnets. This will allow production staff to easily handle and remove them and will protect the magnets and coating. Work with the supplier to determine if special packaging or packaging materials should be considered.
  Never leave magnets unattended. Engineers like to play with magnets, so an unattended magnet can be seen as a project, toy, or experiment.
  Label any package, box or carton that has magnets with a “caution” sticker or hand-written not e stating there are magnets inside. This will give notice to individuals who need to avoid magnets.
  If possible, have these magnets put into a sub-assembly so there is one less handling operation. Most magnet suppliers will make a sub-assembly using steel or some other material.
  Keep the magnets in a clean environment to avoid foreign materials attracting to the magnets. If foreign bodies attach to a medium magnet, pat the magnet with scotch tape or masking tape to remove any foreign materials.
  Large Magnets – >25.4mm
  Always wear safety glasses when handling. If a magnet crashes into another ferrous object it may splinter.
  Always wear gloves with large neodymium magnets to avoid pinching. Remember, fingers and hands can get pinched, bleed or get broken when caught between magnets that snap together so be slow, precise and focused when handling them.
  Large magnets can quickly be attracted to surrounding ferrous materials. Keep them at a safe distance from each other. As a general rule for large magnets, use 15 times the largest dimension as a safe distance. So, if the largest dimension is 2”, keep the magnets 30” from each other, or from other ferrous materials.
  Keep the packaging that the magnet arrived in so you can use it for storage if needed. Many large magnets are installed into equipment, so keep them safe before, during and after installation.
  Control other items around the magnets that are ferrous. Many accidents happen because pliers, screwdrivers, knives, pins, and other ferrous objects jump toward the magnet instead of the magnet jumping toward the other object.
  Watch others who want to “play” with the magnets. Tell them “no”. I once watched a person think it would be fun to take two 1” spheres and place them on each side of his nose. When we left the hospital later…..
  Have a designated area to place the magnet when not using it. This area should be free of tools and other ferrous items.
  If using large magnets in applications in EVT, DVT or mass production, discuss packaging with the magnet supplier. Consider how the assembly staff will handle these large magnets and make sure the packaging is safe and efficient for them.
  If possible, have these magnets put into a sub-assembly so there is one less handling operation. Most magnet suppliers will make a sub-assembly using steel or some other material.
  Keep the magnets in a clean environment to avoid foreign materials attracting to the magnets. If foreign bodies attach to a large Sm2Co17 Magnet pat the magnet with scotch tape or masking tape to remove any foreign materials. https://www.zhijiangmagnet.com